Symptom Chart - Climate Control Systems
Symptom Chart - Climate Control Systems
| Condition |
Possible Sources |
Action |
- The air inlet door is inoperative
|
- Circuitry short/open
- Electronic manual temperature control (EMTC) module
- Air inlet door actuator/linkage
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Circuitry
- Door actuator
- Mode door binding or stuck
- HVAC module
- Door actuator arm not connected to the door crank
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Engine overheating
- Plugged or partially plugged heater core
- Temperature blend door is binding or stuck
- Temperature blend door actuator
- Heater hose is kinked or binding
|
|
- The air conditioning (A/C) is inoperative/does not operate correctly
|
- Fuse
- Circuitry short/open
- A/C system discharged/low charge
- A/C dual function pressure switch
- PCM
- Smart junction box (SJB)
- HVAC module
- A/C cycling switch
- A/C compressor clutch air gap
- A/C clutch relay
|
|
- The air conditioning (A/C) is always ON
|
- Circuitry short
- PCM
- SJB
- A/C compressor clutch air gap
- A/C clutch relay
|
|
- Temperature control is inoperative/does not operate correctly
|
- Circuitry open/shorted
- HVAC module
- Temperature blend door
- Temperature blend door actuator
|
|
- The blower motor is inoperative
|
- Fuse(s)
- Circuitry open/shorted
- A/C blower motor switch
- Blower motor relay
- A/C blower motor
|
|
- The blower motor does not operate correctly
|
- Circuitry short
- A/C blower motor resistor
- A/C blower motor switch
|
|
- Insufficient air conditioning (A/C) cooling
|
- Low refrigerant level
- Temperature blend door actuator
|
|