Pinpoint Test F: The One-Touch Up/Down Feature Is Inoperative - LF
NOTE:
The LF power window motor is not on the multiplex link.
NOTE:
A new LF power window motor will not operate in one-touch up or one-touch down mode until initialized. Refer to Window Motor Initialization .
NOTE:
The LF power window motor must be reinitialized whenever: the motor is removed from the window regulator drum housing, a new motor is installed, a new window regulator is installed, a new window glass is installed, a new top run is installed and when carrying out any operation in which grease or lubricants are applied to the window system.
- F1 CHECK FOR POWER (B+) LOSS DURING LF WINDOW OPERATION
- Verify if power (B+) was lost during LF window operation.
- Was power (B+) lost while LF window was in operation?
- YES : LOWER the LF window to the full open position. MAKE SURE the window glass stalls in the full down position for at least a half second. Normal functionality should resume. TEST the system for normal operation.
- NO : Go to F2.
- F2 INITIALIZE THE LF MOTOR
- Carry out the LF window motor initialization procedure. Refer to Window Motor Initialization .
- Are the one-touch up/down functions operating correctly?
- YES : Repair is complete. TEST the system for normal operation.
- NO : Go to F3.
- F3 CHECK THE MASTER WINDOW CONTROL SWITCH
- Carry out the front window switch component test. Refer to COMPONENT TESTING.
- Did the front window switch pass the component test?
- YES : For Expedition, go to F4.
- For Navigator, go to F5.
- NO : INSTALL a new master window control switch. REFER to Window Control Switch . TEST the system for normal operation.
- F4 CHECK THE FRONT WINDOW SWITCH TO LF MOTOR FEEDS
- Key in OFF position.
- Open the front door to disable delayed accessory power.
- Disconnect: Master Power Window Control Switch C504A
- Disconnect: LF Power Window Motor C540
- Measure the resistance between LF power window motor C540-7, circuit CPW11 (BU/GY) and master window control switch C504A-5, circuit CPW11 (BU/GY); C540-4, circuit CPW10 (YE/VT) and C504A-1, circuit CPW10 (YE/VT); C540-6, circuit CPW29 (VT/GY) and C504A-7, circuit CPW29 (VT/GY) harness side.
- Are the resistances less than 5 ohms?
- YES : Go to F6.
- NO : REPAIR circuit CPW11 (BU/GY), CPW10 (YE/VT) or CPW29 (VT/GY) for an open. REINITIALIZE the LF power window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
- F5 CHECK THE FRONT WINDOW SWITCH TO LF MOTOR FEEDS
- Key in OFF position.
- Open the front door to disable delayed accessory power.
- Disconnect: Master Power Window Control Switch C535A
- Disconnect: LF Power Window Motor C540
- Measure the resistance between LF power window motor C540-7, circuit CPW11 (BU/GY) and master window control switch C535A-4, circuit CPW11 (BU/GY); C540-4, circuit CPW10 (YE/VT) and C535A-7, circuit CPW10 (YE/VT); C540-6, circuit CPW29 (VT/GY) and C535A-8, circuit CPW29 (VT/GY) harness side.
- Are the resistances less than 5 ohms?
- YES : Go to F6.
- NO : REPAIR circuit CPW11 (BU/GY), CPW10 (YE/VT) or CPW29 (VT/GY) for an open. REINITIALIZE the LF power window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
- F6 CHECK FOR AN INTERMITTENT GROUND CONNECTION
- Key in OFF position.
- Measure the resistance between LF power window motor C540-8, circuit GD143 (BK/VT) harness side and ground.
- Wiggle the harness while measuring the resistances.
- Is the resistance less than 5 ohms?
- YES : Go to F7.
- NO : REPAIR circuit GD143 (BK/VT) for an open. REINITIALIZE the LF power window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
- F7 CHECK FOR INTERMITTENT POWER CONNECTIONS
- Key in ON position.
- Measure the voltage between LF power window motor C540-3, circuit SBP01 (RD) and C540-2, circuit CPB41 (BU) harness side and ground.
- Wiggle the harness while measuring the voltages.
- Are the voltages greater than 10 volts?
- YES : INSTALL a new LF power window motor. REFER to Window Regulator Motor - Front Door . REINITIALIZE the LF power window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
- NO : VERIFY smart junction box (SJB) fuse 1 (30A) and fuse 41 (15A) are OK. If OK, REPAIR circuit SBP01 (RD) or circuit CPB41 (BU) for an open. REINITIALIZE the LF power window motor. REFER to Window Motor Initialization . TEST the system for normal operation.