Electronic Manual Temperature Control (EMTC) System
The EMTC system operation is determined by the settings on the HVAC module - EMTC . The EMTC system is composed of the HVAC module - EMTC , blower motor resistor, mode door actuator, air inlet door actuator and temperature blend door actuator to control the various functions.
The blower motor switch:
- sets the blower motor speed.
- directs the blower motor path to ground through the blower motor resistor to allow blower motor operation in LO, MED-LO and MED-HI.
- directs the blower motor path directly to ground, bypassing the blower motor resistor to allow blower motor operation in HI.
The A/C request button:
- can command the A/C compressor ON (when the function selector switch is in PANEL, FLOOR/PANEL, FLOOR/DEFROST and FLOOR) when the A/C request switch is pressed. Indicator illuminates when A/C request switch is toggled ON.
- is inoperative in MAX A/C, OFF and DEFROST.
- indicator illuminates when the function selector switch is in MAX A/C and cannot be toggled.
- indicator does not illuminate in OFF and cannot be toggled.
- indicator does not illuminate in DEFROST but can be toggled ON or OFF. The A/C compressor will operate regardless of indicator status if the outside air temperature is above 6°C (43°F).
- is serviced only with the climate control module.
The function selector knob:
- selects airflow direction.
The air recirculation button:
- selects either recirculated or outside air source.
- recirculates air in any mode except DEFROST, if requested.
- is disabled in MAX A/C or OFF mode where recirculated air only is used.
- is disabled in DEFROST mode where outside air only is used.
- is serviced only with the climate control module.
The temperature selector knob:
- selects full warm and full cool as well as blended outlet temperatures.
The HVAC module - EMTC also includes:
- a rear window DEFROST button. Refer to GLASS, FRAMES AND MECHANISMS .