Pinpoint Test O: Traction Control System Cannot Be Disabled
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- O1 CHECK FOR COMMUNICATION DTCs
- Check for any ABS module communication DTCs.
Is DTC U0155:00 present?
- Yes : GO to PINPOINT TEST L .
- No : GO to O2 .
- O2 CHECK THE STABILITY TRACTION CONTROL SWITCH STAB_CTRL_SW PID
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: IPC DataLogger.
- Access the IPC PID STAB_CTRL_SW.
- Monitor the PID STAB_CTRL_SW while pressing and releasing the traction control switch.
Does the PID STAB_CTRL_SW show the traction control switch changing from on to off?
- Yes : The system is operating correctly at this time.
- No : GO to O3 .
- O3 CHECK THE STABILITY TRACTION CONTROL SWITCH
- Ignition OFF.
- Disconnect: Stability/Traction Control Switch C2267 .
- Measure the resistance between the traction control switch pin 7, component side, and pin 1, component side while pressing and releasing the switch.
Is the resistance greater than 10, 000 ohms with the switch released and less than 5 ohms with the switch pressed?
- Yes : GO to O4 .
- No : INSTALL a new hazard flasher lamp switch. REFER to EXTERIOR LIGHTING . TEST the system for normal operation.
- O4 CHECK STABILITY/TRACTION CONTROL CIRCUIT FOR AN OPEN
- Measure the resistance between hazard flasher lamp switch C2267-7 , circuit CCA15 (YE/GY), harness side and IPC C220-7 , circuit CCA15 (YE/GY), harness side.
Is the resistance less than 5 ohms?
- Yes : GO to O5 .
- No : REPAIR circuit CCA15 (YE/GY) for an open. TEST the system for normal operation.
- O5 CHECK STABILITY/TRACTION CONTROL CIRCUIT FOR A SHORT TO GROUND
- Measure the resistance between hazard flasher lamp switch C2267-7 , circuit CCA15 (YE/GY), harness side and ground.
Is the resistance greater than 10, 000 ohms?
- Yes : GO to O6 .
- No : REPAIR circuit CCA15 (YE/GY) for a short to ground. TEST the system for normal operation.
- O6 CHECK GROUND CIRCUIT FOR AN OPEN
- Disconnect: Negative Battery Cable.
- Measure the resistance between hazard flasher lamp switch C2267-1 , circuit GD116 (BK/VT), harness side and ground.
Is the resistance less than 5 ohms?
- Yes : GO to O7 .
- No : REPAIR circuit GD116 (BK/VT) for an open. TEST the system for normal operation.
- O7 CHECK THE IPC CONNECTOR
- Ignition OFF.
- Check IPC connector for:
- corrosion
- damaged pins
- pushed-out pins
- Connect the IPC connector and make sure that it is seated correctly.
- Make sure the connector is seated correctly then operate the system and verify the concern is still present.
Is the concern still present?
- Yes : INSTALL a new IPC. REFER to INSTRUMENTATION, MESSAGE CENTER, AND WARNING CHIMES . TEST the system for normal operation.
- No : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector.