Conditions for Setting the DTC
B0223, B0233, B0408
The HVAC control module detects a short to ground, short to voltage, or an open on one of the control circuits.
B0228 02, B0413 02, or B374A 02
The HVAC control module detects the sensor signal out of range. The signal voltage is less than 0.1 V for more than 50 ms.
B0228 05, B0413 05, or B374A 05
The HVAC control module detects the sensor signal out of range. The signal voltage is greater than 4.9 V for more than 50 ms.
B0228 61, B0413 61, or B374A 61
The HVAC control module has commanded the actuator to move, and the sensor signal is not changing or has not moved to the commanded position.
B1395 03
The HVAC control module detects the sensor reference voltage out of range. The reference voltage is less than 0.1 V for more than 50 ms.
B1395 07
The HVAC control module detects the sensor reference voltage out of range. The reference voltage is greater than 4.9 V for more than 50 ms.