Component Testing
S45B Liftgate Control Switch - Interior-Static Test
- Ignition/Vehicle - Off
- Disconnect the electrical connector: S45B Liftgate Control Switch - Interior
- Test for infinite resistance between the test points: Signal terminal 4 & Ground terminal 1 - Not Pressed
- If less than infinite resistance
Replace the component: S45B Liftgate Control Switch - Interior
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 ohms between the test points: Signal terminal 4 & Ground terminal 1 - Pressed
- If 3 ohms or greater
Replace the component: S45B Liftgate Control Switch - Interior
- Go to next step: If less than 3 ohms
- If 3 ohms or greater
- Test for 600 to 700 ohms between the test points: Signal terminal 3 & Ground terminal 1 - Switch S45B in position: Off
- If not between 600 and 700 ohms
Replace the component: S45B Liftgate Control Switch - Interior
- Go to next step: If between 600 and 700 ohms
- If not between 600 and 700 ohms
- Test for 1300 to 1400 ohms between the test points: Signal terminal 3 & Ground terminal 1 - Switch S45B in position: 3/4
- If not between 1300 and 1400 ohms
Replace the component: S45B Liftgate Control Switch - Interior
- Go to next step: If between 1300 and 1400 ohms
- If not between 1300 and 1400 ohms
- Test for 4000 to 5000 ohms between the test points: Signal terminal 3 & Ground terminal 1 - Switch S45B in position: Maximum
- If not between 4000 and 5000 ohms
Replace the component: S45B Liftgate Control Switch - Interior
- Go to next step: If between 4000 and 5000 ohms
- If not between 4000 and 5000 ohms
- All OK.