K39 Liftgate Control Module X2 (TB5 / TC2)
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | Not required | J-35616-4A (PU) | No Tool Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 1 1 |
BU / GY BU / GY |
4682 4682 |
Rear Closure Cinch Latch Motor Release Control Rear Closure Cinch Latch Motor Release Control |
I I |
(TB5/TC2) +(UVB/UV2) (TB5/TC2) -UV2-UVB |
| 2 | 1 1 |
BN BN |
4681 4681 |
Rear Closure Cinch Latch Motor Cinch Control Rear Closure Cinch Latch Motor Cinch Control |
I I |
(TB5/TC2) +(UVB/UV2) (TB5/TC2) -UV2-UVB |
| 3 | 2.5 | RD / GY | 3540 | Battery Positive Voltage | I | (TB5/TC2) |
| 4 | 0.5 0.35 |
RD / GN RD / GN |
2440 2440 |
Battery Positive Voltage Battery Positive Voltage |
I I |
(TC2) /(TB5+UEU) TB5-TC2-UEU |
| 5 | - | - | - | Not Occupied | - | - |
| 6 | 2.5 | BK | 2550 | Ground | I | (TC2/TB5) |