Lock-Up Solenoid Feedback (Tracker A/T)
When ECM energizes lock-up relay, relay energizes lock-up solenoid (if internal transmission oil pressure switch is closed). When energized, the lock-up solenoid will provide a feedback signal to the ECM. This on/off signal is used by ECM with others inputs to control EGR solenoid operation.