No-Load Test
- Remove starter. Connect ammeter in series with starter motor and
fully charged 12-volt battery. See Fig 1. Connect voltmeter
to battery to observe voltage draw readings.
- Connect remote starter or jumper wire to battery and start
terminal of solenoid. Crank starter for maximum of 5 seconds. Starter
drive pinion should extend completely and quickly. Starter should spin
rapidly and smoothly. Current draw should be less than 90 amps at
about 11.5 volts.