Sensor Operating Range Charts
ATMOSPHERIC PRESSURE (PA) SENSOR VOLTAGE TEST
| BARO Pressure - In. Hg |
Volts |
| 0 |
2.8-3.0 |
| 5 |
2.3-2.5 |
| 10 |
1.8-2.0 |
| 15 |
1.3-1.5 |
| 20 |
.8-1.0 |
| 25 |
.3-.5 |
COOLANT TEMPERATURE (TW) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Resistance (Ohms) |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1,000-4,000 |
| 176 (80) |
200-400 |
INTAKE AIR TEMPERATURE (TA) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Resistance (Ohms) |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1,000-4,000 |
| 176 (80) |
200-400 |
MAP SENSOR VOLTAGE TEST
| Vacuum Applied - In. Hg. |
Volts |
| 0 |
2.8-3.0 |
| 5 |
2.3-2.5 |
| 10 |
1.8-2.0 |
| 15 |
1.3-1.5 |
| 20 |
.8-1.0 |
| 25 |
.3-.5 |
EGR LIFT SENSOR VOLTAGE TEST
| Position |
Volts (Approx.) |
| Accord & Prelude |
| Fully Closed |
1.2 |
| Fully Open |
4.0 |
| Civic & CRX |
| Fully Closed |
1.0 |
| Fully Open |
4.5 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
Less Than 0.4 |
| Rich |
Greater Than 0.6 |