Float Test

  1. Make sure the fuel tank is less than half full.
  2. Remove the fuel fill cap to relieve fuel tank pressure, then reinstall the cap.
  3. Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump to the vapor recirculation tube.
    Fig 1: Disconnecting Fuel Tank Vapor Recirculation Tube
    G01475781Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Plug the line (B).
  5. Apply vacuum to the fuel tank vapor recirculation tube.
    • If the vacuum holds, replace the fuel tank vapor control valve (see EVAP Canister Replacement  ).
    • If the vacuum does not hold, the float is OK. Do the valve test.