DTC B1843: UART Communication Error
- Clear the DTC with the HDS.
- Turn the ignition switch to LOCK (0), and then back to ON (II).
- Operate the power seat with the driving position memory switch.
- Check for DTCs with the HDS.
Is DTC B1843 indicated?
YES -Go to next step.
NO -Intermittent failure, the system is OK at this time. Check for loose or poor connections.
- Turn the ignition switch to LOCK (0).
- Disconnect the power seat control unit connectors and power mirror control unit connector (24P).
- Check for continuity between power seat control unit connector B (40P) terminal No. 23 and power mirror control unit (24P) connector terminal No. 24.Fig 1: Checking Continuity Between Power Seat Control Unit Connector B (40P) Terminal No. 23 And Power Mirror Control Unit Connector (24P) Terminal No. 24
Courtesy of ABLE BODY CORP.
Is there continuity?
YES -Go to next step.
NO -Repair an open in the UART wire between the power mirror control unit connector (24P) and power seat control unit connector B (40P).
- Check for continuity between body ground and power seat control unit connector B (40P) terminal No. 23.Fig 2: Checking Continuity Between Body Ground And Power Seat Control Unit Connector B (40P) Terminal No. 23
Courtesy of ABLE BODY CORP.
Is there continuity?
YES -Repair a short to ground in the UART wire.
NO -Go to next step.
- Reconnect the power mirror control unit (24P) connector.
- Measure the voltage between body ground and power mirror control unit connector (24P) terminal No. 13.Fig 3: Measuring Voltage Between Body Ground And Power Mirror Control Unit Connector (24P) Terminal No. 13
Courtesy of ABLE BODY CORP.
Is there battery voltage?
YES -Go to next step.
NO -Check No. A15 (10 A) fuse in the under-hood fuse/relay box. If the fuse is OK, repair an open or high resistance in the wire.
- Turn the ignition switch to ON (II).
- Measure the voltage between body ground and power mirror control unit connector (24P) terminal No. 15.Fig 4: Measuring Voltage Between Body Ground And Power Mirror Control Unit Connector (24P) Terminal No. 15
Courtesy of ABLE BODY CORP.
Is there 0.2 V or more?
YES -Replace the power mirror control unit (see POWER MIRROR CONTROL UNIT INPUT TEST/REPLACEMENT ).
NO -Repair an open or high resistance in the wire between the power mirror control unit and G401. If the wire is OK, repair G401.