Power Window Master Switch Connector For Inputs And Outputs (2019 2020 2021)
Power Window Master Switch 37P Connector (female terminals)
| Terminal number | Terminal name | Description | Signal |
|---|---|---|---|
| 1 | DR DN | Drives driver's power window motor | When driver's power window motor DOWN operation: about battery voltage If none of above conditions are met: less than 0.2 V |
| 2 | DR UP | Drives driver's power window motor | When driver's power window motor UP operation: about battery voltage If none of above conditions are met: less than 0.2 V |
| 3 | PGND | Ground for power window master switch | Less than 0.2 V at all times |
| 4 | +B DR P/W | Power source for door multiplex control unit | About battery voltage at all times |
| 5 | R/C MIRR MTR (L-UD) | Detects R/C MIRR MTR (L-UD) signal | When vehicle in ON mode: about 0 V or 5 V (depending on power mirror switch position) |
| 6 | R-LR | Detects R-LR signal | With power mirror selector switch in R position: less than 0.2 V |
| 7 | R-UD | Detects R-UD signal | With power mirror selector switch in R position: less than 0.2 V |
| 8 | RETRA DR CLOSE | Drives retract actuator | When vehicle in ON mode and power mirror retract operation: about battery voltage If none of above conditions are met: less than 0.2 V |
| 9 | RETRA DR OPEN | Drives retract actuator | When vehicle in ON mode and power mirror extend operation: about battery voltage If none of above conditions are met: less than 0.2 V |
| 10 | M-IND1 | Outputs M-IND1 signal | Indicator 1 ON: pulse (depending on indicator brightness) Indicator 1 OFF: less than 0.2 V |
| 11 | RETRA SW | Outputs RETRA SW signal | With vehicle in ON mode and power mirror retract switch in EXTEND position: less than 0.2 V With vehicle in ON mode, and power mirror retract switch in RETRACT position: about battery voltage |
| 12 | M-IND2 | Outputs M-IND2 signal | Indicator 2 ON: pulse (depending on indicator brightness) Indicator 2 OFF: less than 0.2 V |
| 13 | DR SVCC | Outputs DR SVCC signal | With door multiplex control unit is wakeup mode: about battery voltage With door multiplex control unit is sleep mode: less than 0.2 V |
| 14 | FUEL LID SW+ | Detects FUEL LID SW+ signal | With fuel fill door opener switch OFF: about battery voltage With fuel fill door opener switch ON: less than 0.2 V |
| 15 | L HEAT MIR | Outputs L HEAT MIR signal | With mirror defogger ON mode: about battery voltage |
| 16 | RL RLY UP | Drives left rear power window motor | With left rear power window moving to UP using power window master switch: about battery voltage If none of above conditions are met: less than 0.2 V |
| 17 | DR PLSA | DR PLSA signal | - - - |
| 18 | RR RLY UP | Drives right rear power window motor | With right rear power window moving to UP using power window master switch: about battery voltage If none of above conditions are met: less than 0.2 V |
| 19 | DR PLSB | DR PLSB signal | - - - |
| 20 | M-SET | Detects M-SET signal | With driving position memory set switch ON: less than 0.2 V With driving position memory set switch OFF: about battery voltage |
| 21 | Not used | - - - | - - - |
| 22 | M-POS1 | Detects M-POS1 signal | With driving position memory switch 1 ON: less than 0.2 V With driving position memory switch 1 OFF: about battery voltage |
| 23 | M-POS2 | Detects M-POS2 signal | With driving position memory switch 2 ON: less than 0.2 V With driving position memory switch 2 OFF: about battery voltage |
| 24 | Not used | - - - | - - - |
| 25 | IG2 A/C | IG2 power source | With vehicle in ON mode: about battery voltage |
| 26 | +B BACKUP | Power source for power window master switch | About battery voltage at all times |
| 27 | RL RLY DN | Drives left rear power window motor | With left rear power window moving to DOWN using power window master switch: about battery voltage If none of above conditions are met: less than 0.2 V |
| 28 | B-CAN_H | Communication line | - - - |
| 29 | RR RLY DN | Drives right rear power window motor | With right rear power window moving to DOWN using power window master switch: about battery voltage If none of above conditions are met: less than 0.2 V |
| 30 | B-CAN_L | Communication line | - - - |
| 31 | GND | Ground for power window master switch | Less than 0.2 V at all times |
| 32 | DR SILCON UNLOCK | Detects DR SILCON UNLOCK signal | With driver's door lock knob switch LOCK: about battery voltage With driver's door lock knob switch UNLOCK: less than 0.2 V |
| 33 | DR SILCON LOCK | Detects DR SILCON LOCK signal | With driver's door lock knob switch UNLOCK: about battery voltage With driver's door lock knob switch LOCK: less than 0.2 V |
| 34 | DR K/CYL UNLOCK | Detects DR K/CYL UNLOCK signal | With driver's door key cylinder switch LOCK: about battery voltage With driver's door key cylinder switch UNLOCK: less than 0.2 V |
| 35 | DR K/CYL LOCK | Detects DR K/CYL LOCK signal | With driver's door key cylinder switch UNLOCK: about battery voltage With driver's door key cylinder switch LOCK: less than 0.2 V |
| 36 | LIN (WINDOW) | Communication line | - - - |
| 37 | ILLUMI+PW | Detects ILLUMI+PW signal | With combination light switch PARKING: about battery voltage With combination light switch OFF: less than 0.2 V |