DTC P06B4 (Generator Motor Control Module): General Description
Courtesy of HONDA, U.S.A., INC.
|
The power control unit (PCU) controls the motor output based on the generator phase V current sensor signals. When the power supply voltage is out of a specified range for a set time, the motor control module in the PCU detects a malfunction and stores a DTC.