Keyless Access System Status Log
If you suspect there is an immobilizer system problem, check the status log in the HDS.
1. Connect the HDS to the data link connector (DLC) How to Connect the HDS
2. Turn the vehicle to the ON mode.
3. On the HDS screen, at SYSTEM SELECTION MENU, enter ONE-PUSH START, then select KEYLESS ACCESS CONTROL UNIT or BACKUP CONTROL UNIT.
NOTE:
If the HDS does not communicate, check the keyless access/TPMS control unit power, ground, K-line, and L-line connectors.
4. At KEYLESS ACCESS CONTROL UNIT, enter KEYLESS ACCESS SYSTEM INFORMATION, then select KEYLESS ACCESS STATUS LOG.
5. At BACKUP CONTROL UNIT, enter SYSTEM INFORMATION, then select STATUS LOG.
6. Check the STATUS LOG count. Troubleshoot the status with the highest count first. If no counts are listed, the immobilizer system is OK. Continue with normal symptom troubleshooting.
Status Log (Keyless Access/TPMS Control Unit)
| Status Log No. |
Possible cause |
B-1 B-2 |
- PCM was not registered correctly
- Keyless access/TPMS control unit was registered correctly
- Poor connections or loose terminals between keyless access/TPMS control unit and PCM
- Poor connections or loose terminals in the IG1 line
- Low 12 volt battery voltage
- Electrical noise
|
C-1 C-2 |
- Communication error between keyless access/TPMS control unit and MICU (Imoes unit)
- Poor connections or loose terminals in the IG1 line
- Keyless access/TPMS control unit was not registered
- Low 12 volt battery voltage
- Electrical noise
|
D-1 D-2 D-3 |
- Poor connections or loose terminals between keyless access/TPMS control unit and MICU (Imoes unit)
- Poor connections or loose terminals between keyless access/TPMS control unit and PCM
- Low 12 volt battery voltage
- Electrical noise
- Blown fuse
|
Status Log (Backup Control Unit)
| Status Log No. |
Possible cause |
A-1 A-2 A-3 |
- Keyless remote was not registered correctly
- Engine start/stop switch failure
|
B-1 B-2 |
- PCM was not registered correctly
- Communication error between keyless access/TPMS control unit and PCM
- Low 12 volt battery voltage
- Electrical noise
|
C-1 C-2 |
- Keyless access/TPMS control unit was not registered correctly
- Communication error between keyless access/TPMS control unit and MICU (Imoes unit)
- Poor connections or loose terminals in the IG1 SAFETY line
- Low 12 volt battery voltage
- Electrical noise
|
D-1 D-2 D-3 |
- Poor connections or loose terminals between keyless access/TPMS control unit and MICU (Imoes unit)
- Poor connections or loose terminals between keyless access/TPMS control unit and PCM
- S-NET line short
- Low 12 volt battery voltage
- Electrical noise
- Blown fuse
|