September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Resistance Measurement Between Terminals
- Disconnect the connector of the injector and measure the resistance between the two terminals.
Courtesy of HYUNDAI MOTOR CO.
Standard value
: 15.9 +/- 0.35Ω [at 20°C (68°F)]
- Reconnect the connector to the injector.