DTC P0125 Insufficient Coolant Temperature For Closed Loop Fuel Control: Specification

[ECTS] 

DTC P0125 RESISTANCE AND TEMPERATURE SPECIFICATIONS

Temp. (°C) Resistance (kΩ) Temp. (°C) Resistance (kΩ)
-20 14.1 ~ 16.8 40 Approx. 1.2
0 Approx. 5.8 60 Approx. 0.6
20 2.3 ~ 2.6 80 Approx. 0.3

[THERMOSTAT] 

DTC P0125 THERMOSTAT TABLE

THERMOSTAT Normal Parameter
Valve Opening Temp. 80~84 °C
Valve Closing Temp. 77°C
Full Open Lift Approx. 8mm (95°C)