| DTC Strategy |
|
- Short to ground in signal harness
- Contact resistance in connectors.
- Faulty Heated O2 Sensor (HO2S).
|
| Enable Conditions |
- Lambda regulation on Maximum Limit (50%)
- Canister Purge valve closed
- Battery voltage > 10V
- No relevant failure
|
| Threshold Value |
- Sensor voltage < 0,02 V and resistance < 30 Ω
|
| Diagnostic Time |
|
| Fail Safe |
- Reset lambda adaptation and fuel trim adaptation.
- Front HO2S heater is controlled in open loop control.
- EVAP. Emission control function is controlled in minimum operation mode.
|
| Mil On Condition |
|