Monitor Scantool Data
- IG KEY "ON" & Engine "OFF".
- Erase DTC after connecting Scantool.
- Check IPM status parameter if DTC is retrieved
It shows that 2 (two) FOB key is registered, Smart Key ECM (integrated in IPM) is learnt status.
- Is the smart Key ECM (Integrated in IPM) learnt?
YES
- Fault is intermittent caused by poor contact in Smart ECM and/or ECM's connector or was repaired and Smart key ECM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Go to Wire Harness Inspection procedure .