Inhibitor Switch: Installation
- Temporarily install the neutral start switch with the new seal bolt.
Bolt size (10): M8x1.25x30mm (Seal bolt)
CAUTION: Tighten the bolt after adjusting the neutral start switch to "N" position. - Install the washer and the lock washer with the nut.
Tightening torque :
6~8 Nm (0.6~0.8 kgf.m, 4.34~5.78 lb-ft)
- Using a screwdriver, stake the lock washer.
- Adjust the manual valve lever shaft to "N" position.
- Set SST to the manual valve lever shaft.
- Align the reference line of the special service tool (09452-3M400) with the neutral reference line of the neutral start switch, and tighten the bolt.
Tightening torque :
10~16 Nm (1.0~1.6 kgf.m, 7.23~11.57 lb-ft)
- Adjust the manual valve lever shaft to "P" position.
- Install the shift control cable assembly and the connector to the neutral start switch.