[Position Sensor]
- Turn ignition switch OFF.
- Connect the GDS to the data link connector (DLC).
- Check the output voltage at each position of the EWGA position sensor on current data component within the specification.
Specification: Refer to "SPECIFICATION "
Information
- When the fault code P2562/3/5 is detected, make adjustment first. Then, check whether the same fault code is detected.