Repair Procedures: Removal
- Set shift lever to "N" position.
- Remove the air duct.
(Refer to "AIR CLEANER ")
- Remove the battery and the battery tray.
(Refer to "BATTERY ")
- Disconnect the inhibitor switch connector (A).
- Remove the shift cable mounting nut (B).
Tightening torque:
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)
- Remove the manual control lever (B) and the washer after removing a nut (A).
Tightening torque:
17.7 ~ 24.5 N.m (1.8 ~ 2.5 kgf.m, 13.0 ~ 18.1 lb-ft)
- Remove the inhibitor assembly (A) after removing the bolts (2ea).
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
CAUTION: When installing, tighten the inhibitor assembly mounting bolt to the specification shown above.