ECM Terminal Input/Output signal

CONNECTOR (C300-A) DESCRIPTION

Pin No Description Condition Type Level
1       Operating freq.: 1000 Hz (estimated)
Forward direction
2 ETC Motor [+] control output Idle PWM Turn on: Battery voltage Frewheeling: Max. 0.1V Reverse direction Turn on: Max. 0.1V Frewheeling: Max. 0.1V
3 EGR Motor [+] Control Output      
4 Motor [-] control output      
5 -      
6 -      
7 -      
8 -      
9 -      
10 Clutch switch signal input [M/T] Switch ON Switch OFF Digital Min. -0.3V- Max. 0.5V Battery voltage
11 -      
12 -      
13 -      
14 -      
15 Sensor ground Idle DC Max. 0.5V
16 Engine Coolant Temperature Sensor (ECTS) signal input Idle Analog Min. 0.1V- Max
17 Throttle Position Sensor (TPS) 2 signal input Idle Analog Min. 0.4V - Max. 4.5V
18 -      
19 -      
20 -      
21 Sensor power (+5V) IG OFF IG ON DC voltage Max. 0.5V
4.9-5.1V
22       Operating freq.: 1000 Hz (estimated)
Forward direction
23 ETC Motor [-] control output Idle PWM Turn on: max 0.1V Frewheeling: max 0.1V
Reverse direction Turn on: Battery voltage Frewheeling: max 0.1V
24 EGR Motor [-] Control Output      
25 Motor [+] control output      
26 -      
27 -      
28 -      
29 -      
30 -      
31 Electrical load signal input Idle PWM Freq.: 125 Hz or 200 Hz or 60 Hz Duty rate 0%-100%
32 -      
33 -      
34 -      
35 -      
36 -      
37 Sensor ground Idle DC Max. 0.5V
38 Throttle Position Sensor (TPS) 1 signal input Idle Analog Min. 0.4V - Max. 4.5V
39 -      
40 Alternator PWM control output IG OFF IG ON PWM Battery voltage Max. 0.5V
41 -      
42 Sensor power (+5V) IG OFF IG ON DC Max. 0.5V
Min. 4.75V - Max. 5.25V
43 -      
44 -      
45 -      
46 -      
47 -      
48 -      
49 -      
50 -      
51 -      
52 -      
53 -      
54 VCMA Feedback ground      
55 -      
56 Camshaft Position Sensor (CMPS) [Bank 1/Exhaust] signal input Idle Pulse Around 7 Hz at 850 RPM
Around 25 Hz at 3000 RPM
57 -      
58 -      
59 Feedback Sensor Ground Idle DC Max. 50 mV
60 -      
61 Sensor ground Idle DC Max. 0.5V
62 Manifold Absolute Pressure Sensor (MAPS) signal input Idle Analog Min. 0.8V - Max. 4.2V
63 Sensor power (+5V) IG OFF IG ON DC voltage Max. 0.5V 4.9 - 5.1V
64 -      
65 -      
66 -      
67 -      
68 -      
69 -      
70 -      
71 -      
72 -      
73 -      
74 Sensor ground Idle DC Max. 0.5V
75 -      
76 VCMA Feedback signal input      
77 Camshaft Position Sensor (CMPS) [Bank 1/Exhaust] signal input Idle Pulse Around 7 Hz at 850 RPM
Around 25 Hz at 3000 RPM
78 Sensor ground Idle DC Max. 0.5V
79 -      
80 -      
81 -      
82 -      
83 VG (Virtual Ground) Idle Analog Min. 0.2V - Max. 5.2V
84 VN (NERNST Cell Voltage) Idle Analog Min. 0.2V - Max. 5.2V
85 -      
86 -      
87 -      
88 -      
89 -      
90 -      
91 -      
92 -      
93 -      
94 -     Vpp Min.: 18V at Idle (for 1 rail)
95 Crankshaft Position Sensor (+) signal input Idle Frequency Vpp Max.: 90V at 5000 RPM (for 1 rail)
96 -      
97 -      
98 Camshaft Position Sensor (CMPS) [Bank 1/Intake] signal input Idle Pulse Around 7 Hz at 850 RPM
Around 25 Hz at 3000 RPM
99 Sensor ground Idle DC Max. 0.5V
100 Knock Sensor (KS) signal input Idle Analog/Frequency Freq.: Min. 8 kHz - Max. 12 kHz
Level: Min. 180 - Max. 300 mVpp
101 Intake Air Temperature Sensor (IATS) signal input Idle Analog Min. 0.1V - Max. 4.7V
102 Feedback Signal Input      
103 -      
104 VN (NERNST Cell Voltage) Idle Analog Min. 0.2V - Max. 5.2V
105 VIP (Current Pump) Idle Analog Min. 0.2V - Max. 5.2V
CONNECTOR (C300-B) DESCRIPTION

Pin No Description Condition Type Level
1 Power ground Idle DD Mx 0Va.5m
2 Power ground Idle DC Max. 50 mV
3 Battery power (B+) IG OFF DC Max. 0.5V
IG ON Battery Voltage
4 Power ground Idle DC Max. 50 mV
5 Battery power (B+) IG OFF DC Max. 0.5V
IG ON Battery Voltage
6 Battery power (B+) IG OFF DC Max. 0.5V
IG ON Battery Voltage
7 -      
8 FLEX-RAY (High)      
9 -      
10 Accelerator Position Sensor (APS) 2 signal input Idle Analog Min. 0.6V - Max. 4.3V
11 A/C Pressure Transducer (APT) signal input      
12 -      
13 -      
14 Sensor power (+5V) IG OFF DC Max. 0.5V
IG ON Min. 4.75V - Max. 5.25V
15 -      
16 Sensor power (+5V) IG OFF DC Max. 0.5V
IG ON Min. 4.75V - Max. 5.25V
17 Sensor power (+5V) IG OFF DC Max. 0.5V
IG ON Min. 4.75V - Max. 5.25V
18 Main Relay control output Relay OFF DC Battery Voltage
Relay ON   Min. -0.3V -Max. 1.2V
19 Fuel Pump Relay control output Relay OFF DC Battery Voltage
Relay ON   Min. -0.3V -Max. 1.2V
20 -      
21 -      
22 Injector (Cylinder #2) control output Idle DC High: Battery voltage
Low: Max. 0.5V
48 - 50V
23 Injector (Cylinder #3) control output Idle DC High: Battery voltage
Low: Max. 0.5V
48 - 50V
24 -      
25 FLEX-RAY (Low)      
26 Electrical signal input [Blower Max. Switch]      
27 Accelerator Position Sensor (APS) 1 signal input Idle Analog Min. 0.6V - Max. 4.3V
28 Sensor ground Idle DC Max. 50 mV
29 Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 2] signal input Idle Analog
DC
Min. 0.6V - Max. 1.0V
30 Fuel Tank Pressure Sensor signal input      
31 -      
32 -      
33 -      
34 Start Motor control switch Switch ON
Switch OFF
Digital Battery voltage
Min. -0.3V - Max. 0.5V
35 CVVT Oil Control (OCV) Valve [Bank 1/Exhaust] control output Idle PWM Operating freq. range: 300 Hz
Duty rate: 0% - 100%
36 CVVT Oil Control (OCV) Valve [Bank 1/Intake] #1 control output Idle PWM Operating freq. range: 300 Hz
Duty rate: 0% - 100%
37 -      
38 A/C Relay control output Relay OFF
Relay ON
DC Battery Voltage
Min. -0.3V -Max. 1.2V
High: Battery voltage
39 Injector (Cylinder #4) control output Idle DC Low: Max. 0.5V
48 - 50V
40 Ignition Coil (Cylinder #2) control output
Ignition Coil (Cylinder #3) control output
Idle Pulse Turn on: Max. 1.6V
Turn off: Battery voltage
41 Battery power (B+) IG OFF
IG ON
DC Max. 0.5V
Battery Voltage
42 -      
43 -      
44 -      
45 Sensor ground Idle DC Max. 50 mV
46 Sensor ground Idle DC Max. 50 mV
47 Sensor ground Idle DC Max. 50 mV
48 -      
49 -      
50 Sensor ground Idle DC Max. 50 mV
51 -      
52 -      
53 -      
54 Canister Close Valve (CCV) control output      
55 CVVT Oil Control (OCV) Valve [Bank 1/Intake] #2 control output     High: Battery voltage
56 Injector (Cylinder #1) control output Idle DC Low: Max. 0.5V
48 - 50V
57 Ignition Coil (Cylinder #1) control output
Ignition Coil (Cylinder #4) control output
Idle Pulse Turn on: Max. 1.6V
Turn off: Battery voltage
58 -      
59 -      
60 C-CAN [Low] RECESSIVE DOMINANT Pulse 2.0 - 3.0V
0 - 0.5V
61 Fuel Tank Level Sensor signal input      
62 -      
63 -      
64 -      
65 Brake Light Switch signal input Switch ON Digital Battery voltage
Switch OFF Min. -0.3V - Max. 0.5V
66 Start signal input      
67 Engine speed signal output Idle Frequency Around 26 Hz at 850 RPM, idle
Around 16 Hz at 3000 RPM
68 Immobilizer communication line When Pulse High: Min. 8.5V
communicating
after IG ON
  Low: Max. 3.5V
69 -      
70 -      
71 Purge Control Solenoid Valve (PCSV) control output Relay OFF DC Battery voltage
Relay ON Max. 1.76V
72 Electronic Thermo Sensor signal input      
73 Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 1] Heater control output Relay OFF DC Battery voltage
Relay ON Max. 0.5V
74 Ignition Coil (Cylinder #2) control output Idle Pulse Turn on: Max. 1.6V
Ignition Coil (Cylinder #3) control output Turn off: Battery voltage
75 -      
76 -      
77 C-CAN [High] RECESSIVE Pulse 2.0 - 3.0V
DOMINANT 2.75 - 4.5V
78 -      
79 Vehicle speed signal input Idle Frequency Duty rate 40% - 60%
80 Electrical load signal input [Wiper]      
81 -      
82 -      
83 Brake Test Switch signal input Switch ON Digital Battery voltage
Switch OFF Min. -0.3V - Max. 0.5V
84 -      
85 LIN communication      
86 Cooling Fan Relay [Low] control output IG OFF PWM Battery voltage
IG ON Min. -0.3V - Max. 1.2V
87 Cooling Fan Relay [High] control output IG OFF DC Battery voltage
IG ON Min. -0.3V - Max. 1.2V
88 Variable Intake Solenoid (VIS) Valve control output      
89 -      
90 Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 2] Relay OFF DC Battery voltage
Heater control output Relay ON Max. 0.5V
91 Ignition Coil (Cylinder #1) control output Idle Pulse Turn on: Max. 1.6V
Ignition Coil (Cylinder #4) control output Turn off: Battery voltage