Repair Procedures: Removal
- Disconnect the battery negative (-) cable.
- Remove the battery. (Refer to Charging System - "BATTERY ")
- Disconnect the battery sensor connector (A).
- Remove the battery negative (-) cable after removing the bolt (B).
Battery negative (-) terminal tightening nut:
4.0 - 6.0 N.m (0.4 - 0.6 kgf.m, 3.0 - 4.4 lb.ft)
Battery sensor cable installation bolt:
10.8 - 13.7 N.m (1.1 - 1.4 kgf.m, 8.0 - 10.1 lb - ft)