Feedback Position Sensor
- Connect the diagnostic tool to the data link connector.
- Perform the fully open and the fully closing operation of the EEGR valve by using the actuation test.
- Check that the voltage is within the specification
- Specification
Item Specification Sensor Power (V) 5 Opened Voltage (V) 3.85 - 4.15 Closed Voltage (V) 0.85 - 1.15