(RCV Control Solenoid Valve Removal And Installation)
ABBREVIATED PROCEDURE
| Work | H/W | Tightening torque N.m (kgf.m/lb-ft) | SST/Equipment | Chemical | etc | |
|---|---|---|---|---|---|---|
|
||||||
| 1 | Disconnect the battery negative (-) terminal | - | - | - | - | - |
| 2 | Remove the air cleaner assembly (Refer to Engine Mechanical System - "AIR CLEANER ") |
- | - | - | - | - |
| 3 | Disconnect the RCV control solenoid valve connector | - | - | - | - | - |
| 4 | Separate the vacuum hose by releasing the clamp | - | - | - | - | - |
| 5 | Remove the RCV control solenoid valve after removing the bolt | Bolt | 9.8 - 11.8 (1.0 - 1.2/7.2 - 8.7) | - | - | - |
|
||||||
| Install in the reverse order of removal | - | |||||