Sensor Range Charts
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
CAMSHAFT POSITION (CMP) SENSOR RESISTANCE
| Application - @ 68°F (20°C) |
Ohms |
| Hitachi |
1440-1760 |
| Mitsubishi |
2090-2550 |
CRANKSHAFT POSITION (CKP) SENSOR RESISTANCE
| Temperature |
Ohms |
| 68°F (20°F) |
166-204 |
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE
| Temperature |
Ohms |
| 68°F (20°C) |
2100-2900 |
| 122°F (50°C) |
680-1000 |
| 194°F (90°C) |
236-260 |
| 230°F (110°C) |
143-153 |
EGR TEMPERATURE SENSOR RESISTANCE
| Temperature |
Ohms |
| 32°F (0°C) |
790,000-970,000 |
| 122°F (50°C) |
570,000-700,000 |
| 212°F (100°C) |
80,000-100,000 |
HEATED OXYGEN SENSOR (HO2S) RESISTANCE
| Condition |
Ohms |
| Front |
3.3-6.3 |
| Rear |
5.2-8.2 |
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE
| Temperature |
Ohms |
| 68°F (20°C) |
2100-2900 |
| 176°F (80°C) |
270-380 |
THROTTLE POSITION (TP) SENSOR RESISTANCE
| Application |
Ohms |
| Completely Released |
1000 |
| Partially Released |
1000-10,000 |
| Completely Depressed |
10,000 |
MASS AIRFLOW (MAF) SENSOR VOLTAGE SPECIFICATIONS
| Application |
Power Supply Volts |
Output Supply Volts |
| G20 |
11.0-14.0 |
1.3-1.7 |