1. Check Key Switch Input Signal
With CONSULT-II
Check ignition key switch "KEY ON SW" in "DATA MONITOR" mode with CONSULT-II.
- When key is inserted in ignition key cylinder
- KEY ON SW : ON
- When key is removed from ignition key cylinder
- KEY ON SW : OFF
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK : Key switch circuit is OK.
NG : GO TO 2 (with intelligent key)
NG : GO TO 3 (without intelligent key)