IPDM E/R Power/Ground Circuit Inspection
- CHECK FUSE AND FUSIBLE LINK
- Make sure the following fusible links or IPDM E/R fuses are not blown.FUSIBLE LINK IDENTIFICATION
Terminal No. Signal Name Fuse, Fusible Link No. 1,2 Battery Power F/L-C, F/L-E, Fuse No. 71, 78
OK or NG
- OK: GO TO 2.
- NG: Replace fuse or fusible link.
- Make sure the following fusible links or IPDM E/R fuses are not blown.
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector E3.
- Check voltage between IPDM E/R harness connector E3 terminals 1 (W/R), 2 (W/L) and ground.
- 1 (W/R), 2 (W/L) - Ground: Battery voltage should exist
OK or NG
- OK: GO TO 3.
- NG: Replace IPDM E/R power supply circuit harness.
- CHECK GROUND CIRCUIT
- Disconnect IPDM E/R harness connectors E8 and E9.
- Check continuity between IPDM E/R harness connectors E8 terminal 38 (B), E9 terminal 50 (B/W), 60 (B/W) and ground.
- 38 (B), 50 (B/W), 60 (B/W) -: Continuity should exist Ground
OK or NG
- OK: INSPECTION END
- NG: Replace ground circuit harness of IPDM E/R.