Home >> Infiniti >> 2004 >> G35 x >> Repair and Diagnosis (Single Page) >> Electrical >> Body Electrical >> 2004 - IPDM E/R (Intelligent Power Distribution Module Engine Room) - Sedan >> IPDM E/R (Intelligent Power Distribution Module Engine Room) >> System Description >> CAN Communication Line Control
April 5, 2026: LEMON Manuals is launched! Read the announcement.

CAN Communication Line Control

With CAN communication, by connecting each control unit using two communication lines (CAN L-line, CAN H-line), it is possible to transmit maximum amount of information with minimum wiring. Each control unit can transmit and receive data, and reads necessary information only.

  1. Fail-safe control
    • When CAN communication with other control units is impossible, IPDM E/R performs fail-safe control. After CAN communication recovers normally, it also returns to normal control.
    • Operation of control parts by IPDM E/R during fail-safe mode is as follows:
    Fig 1: IPDM E/R Control Parts Operation During Fail-Safe Mode Table
    G02526723Courtesy of NISSAN MOTOR CO., U.S.A.