LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2008 >> EX35 Base, AWD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Windows >> Power Window Control System >> Basic Inspection >> Inspection And Adjustment >> Additional Service When Replacing Control Unit >> Special Repair Requirement >> Initialization Procedure
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Initialization Procedure

  1. Disconnect battery negative terminal or power window main switch connector. Reconnect it after a minute or more.
  2. Turn ignition switch ON.
  3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
  4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.
  5. Initializing procedure is completely.
  6. Inspect anti-pinch function.