Diagnostic Procedure
- CHECK POWER SUPPLY CIRCUIT
With CONSULT-III
Check ("IGN ACC SW") in DATA MONITOR mode with CONSULT-III.
When ignition switch is turned to ACC
ACC ON SW: ON
Without CONSULT-III
Check voltage between Intelligent Key unit connector and ground.
VOLTAGE REFERENCE CHARTTerminals Ignition switch condition Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M32 30 Ground ACC Battery voltage OFF 0 Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: ACC power circuit is OK. Check the self-diagnosis results using CONSULT-III again.
NG: GO TO 2.
- CHECK COMMUNICATION CIRCUIT
- Turn ignition switch OFF.
- Disconnect Intelligent Key unit and power distribution unit connector.
- Check continuity between Intelligent Key unit connector and power distribution unit connector.CONTINUITY REFERENCE CHART
A B Continuity Intelligent Key unit connector Terminal Power distribution unit connector Terminal M33 42 M30 1 Yes - Check continuity between Intelligent Key unit connector and ground.
Courtesy of NISSAN MOTOR CO., U.S.A.
CONTINUITY REFERENCE CHARTA Ground Continuity Intelligent Key unit connector Terminal M33 42 No OK or NG
OK: GO TO 3.
NG: Repair or replace harness.
- CHECK POWER SUPPLY CIRCUIT 2
- Connect Intelligent Key unit and power distribution unit connector.
- Check voltage between Intelligent Key unit connector and ground.
VOLTAGE REFERENCE CHARTTerminals Ignition switch condition Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M32 30 Ground ACC Battery voltage OFF 0 Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: Check the condition of harness and connector. If it is OK, check the self-diagnosis results using CONSULT-III again.
NG: Check the following.
- 10A fuse [No. 6, located in the fuse block (J/B)]
- Harness for open or short between fuse and Intelligent Key unit.