Diagnosis Procedure
- INSPECTION START
Perform inspection in accordance with procedure that confirms DTC.
Which procedure confirms DTC?
DTC confirmation procedure 1: GO TO 2.
DTC confirmation procedure 2: GO TO 5.
- CHECK STARTER RELAY OUTPUT SIGNAL
- Check voltage between BCM harness connector and ground.CONNECTOR TERMINALS VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (V) (Approx.) BCM Connector Terminal M70 97 Ground Selector lever (CVT models) P or N position 12 Other than above 0 Clutch pedal (M/T models) Depressed 12 Not depressed 0 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- Check voltage between BCM harness connector and ground.
- CHECK STARTER RELAY OUTPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Disconnect IPDM E/R connector.
- Check continuity between BCM harness connector and IPDM E/R harness connector.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
BCM IPDM E/R Continuity Connector Terminal Connector Terminal M70 97 E13 30 Existed - Check continuity between BCM harness connector and ground.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M70 97 Not existed Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK STARTER RELAY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check voltage between IPDM E/R harness connector and ground.CONNECTOR TERMINALS VOLTAGE REFERENCE CHART
(+) (-) Voltage (V) IPDM E/R Connector Terminal E10 4 Ground 9 - 16 Is the inspection result normal?
YES: GO TO 7.
NO: Check harness for open or short between IPDM E/R and battery. Refer to "M/T : WIRING DIAGRAM " (M/T models), or "CVT : WIRING DIAGRAM " (CVT models).
- CHECK IGNITION POWER SUPPLY NO. 2 SIGNAL
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check voltage between IPDM E/R harness connector and ground.CONNECTOR TERMINALS VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (V) IPDM E/R Connector Terminal E17 69 Ground Power supply position OFF 0 - 1 ON 6 - 16 Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: GO TO 6.
- CHECK BCM INPUT SIGNAL CIRCUIT
- Disconnect BCM connector.
- Check continuity between IPDM E/R harness connector and BCM harness connector.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
IPDM E/R BCM Continuity Connector Terminal Connector Terminal E17 69 M70 101 Existed - Check continuity between transmission range switch harness connector and ground.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
IPDM E/R Ground Continuity Connector Terminal E17 69 Not existed Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace harness.
- REPLACE BCM
- Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- Perform DTC CONFIRMATION PROCEDURE for DTC B210E. Refer to
, "DTC LOGIC ".
Is the inspection result normal?
YES: INSPECTION END
NO: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".