Recirculating-To-Discharge Air Temperature Table

WARNING: This page is about a different car, the 2011 Infiniti QX56. However, it is still accessible from the selected car via links, so may be relevant.

FRONT

RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE SPECIFICATION

Inside air (Recirculating air) at blower assembly inlet Discharge air temperature from center ventilator °C (°F)
Relative humidity % Air temperature °C (°F)
50 - 60 20 (68) 6.8 - 8.8 (44 - 48)
25 (77) 10.4 - 12.9 (51 - 55)
30 (86) 13.9 - 16.9 (57 - 63)
35 (95) 17.3 - 20.8 (63 - 70)
60 - 70 20 (68) 8.8 - 10.8 (48 - 52)
25 (77) 12.9 - 15.4 (55 - 60)
30 (86) 16.9 - 19.9 (63 - 68)
35 (95) 20.8 - 24.3 (70 - 76)

REAR

AIR TEMPERATURE SPECIFICATION

Inside air (Recirculating air) at blower assembly inlet Discharge air temperature from rear ventilator grille A RH(1) °C (°F)
Relative humidity % Air temperature °C (°F)
50 - 60 20 (68) 11.4 - 13.4 (53 - 56)
25 (77) 15.8 - 18.3 (60 - 65)
30 (86) 20.9 - 23.9 (70 - 75)
35 (95) 25.9 - 29.4 (79 - 85)
60 - 70 20 (68) 13.4 - 15.4 (56 - 60)
25 (77) 18.3 - 20.8 (65 - 69)
30 (86) 23.9 - 26.9 (75 - 80)
35 (95) 29.4 - 32.9 (85 - 91)
(1) Measuring point of temperature is 5 mm (1.99 in) from air outlet end of rear ventilator grille A RH (passenger room side).