Calibrating Camera Image
- Perform the calibration of camera image caused by the incorrect mounting position of each camera, etc. Always perform calibration after performing the following work:
- When each camera or each camera mount (door mirror, front grille, etc.) is removed
- When replacing around view monitor control unit
- When performing the calibration initialization, it can be set to the NISSAN factory shipment condition.
Refer to "CALIBRATING CAMERA IMAGE (AROUND VIEW MONITOR): WORK PROCEDURE " for the calibration procedure.
Adjustment range
Rotating direction: 31 patterns (16 on the center)
Upper/lower direction :--99 - 99
Left/right direction: --99 - 99
CALIBRATING CAMERA IMAGE ITEM LISTItems Description Rear Camera Performs the calibration of rear camera. Pass-Side Camera Performs the calibration of side camera RH. Front Camera Performs the calibration of front camera. Dr-Side Camera Performs the calibration of side camera LH. Initialize Camera Image Calibration* The calibration can be initialized to the factory shipment setting.
CAUTION:
*: Never perform other operations for approximately 10 seconds after performing "Initialize Camera Image Calibration".