SONAR CONTROL UNIT (WITH AROUND VIEW MONITOR): Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
Power source Fuse No. Ignition switch ON or START 4 Is the inspection result normal?
YES: GO TO 2.
NO: Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect sonar control unit connector.
- Check continuity between sonar control unit harness connector and ground.
Sonar control unit Ground Continuity Connector Terminal M47 24 Existed Is the inspection result normal?
YES: INSPECTION END
NO: Repair or replace sonar control unit ground harness.