LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2013 >> M35h >> Repair and Diagnosis (Single Page) >> Brakes >> Traction Control >> Brake Control System (With VDC) >> System Description >> Diagnosis System [Abs Actuator And Electric Unit (Control Unit)] >> CONSULT Function >> Active Test >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Active Test: Notes

The active test is used to determine and identify details of a malfunction, based on self-diagnosis test results and data obtained in the DATA MONITOR. In response to instructions from CONSULT, instead of those from ABS actuator and electric unit (control unit) on the vehicle, a drive signal is sent to the actuator to check its operation.

CAUTION:
  • Never perform ACTIVE TEST while driving the vehicle.
  • Always bleed air from brake system before active test.
  • Never perform active test when system is malfunctioning.
NOTE:
  • When active test is performed while depressing the pedal, the pedal depressing stroke may change. This is not a malfunction.
  • "TEST IS STOPPED" is displayed approx. 10 seconds after operation start.
  • When performing active test again after "TEST IS STOPPED" is displayed, select "BACK".
  • ABS warning lamp, brake warning lamp and VDC warning lamp may turn ON during active test. This is not a malfunction.

ABS IN Valve and ABS OUT Valve

When "Up", "Keep" or "Down" is selected on display screen, the following items are displayed when system is normal.

Test item Display Item Display
Up Keep Down
FR RH SOL FR RH IN SOL Off On(1) On(1)
FR RH OUT SOL Off Off On(1)
FR LH SPL FR LH IN SOL Off On(1) On(1)
FR LH OUT SOL Off Off On(1)
RR RH SOL RR RH IN SOL Off On(1) On(1)
RR RH OUT SOL Off Off On(1)
RR LH SOL RR LH IN SOL Off On(1) On(1)
RR LH OUT SOL Off Off On(1)
(1) Immediately after being selected, status is "On". Status changes to "Off" after approx. 2 seconds.

ABS IN Valve (ACT) and ABS OUT Valve (ACT)

When "Up", "ACT UP" or "ACT KEEP" is selected on display screen, the following items are displayed when system is normal.

Test item Display Item Display
Up ACT UP ACT KEEP
FR RH SOL (ACT) FR RH IN SOL Off Off Off
FR RH OUT SOL Off Off Off
CV1 Off On On
CV1 Off On(1) Off
FR LH SOL (ACT) FR LH IN SOL Off Off Off
FR LH OUT SOL Off Off Off
CV2 Off On On
CV2 Off On(1) Off
RR RH SOL (ACT) RR RH IN SOL Off Off Off
RR RH OUT SOL Off Off Off
CV2 Off On On
CV2 Off On(1) Off
RR LH SOL (ACT) RR LH IN SOL Off Off Off
RR LH OUT SOL Off Off Off
CV1 Off On On
CV1 Off On(1) Off
(1) Immediately after being selected, status is "On". Status changes to "Off" after approx. 10 seconds.