Values On The Diagnosis Tool
NOTE:
The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.
CONSULT MONITOR ITEM DESCRIPTION
| Monitor Item | Condition | Status/Value | |
|---|---|---|---|
| LATCH LOCK SEN | State of roof latch | Lock | ON |
| Other than above | OFF | ||
| Roof latch lock sensor circuit is short | NG | ||
| LATCH STATE SEN | State of roof latch motor | Operate | ON <==> OFF |
| Stop | ON or OFF | ||
| Roof latch lock sensor circuit is short | NG | ||
| LATCH OUT (ULK) | Operation of roof latch motor | Unlock is in operation | ON |
| Other than above | OFF | ||
| Roof latch motor (UNLOCK) circuit is short | NG | ||
| LATCH OUT (LCK) | Operation of roof latch motor | Lock is in operation | ON |
| Other than above | OFF | ||
| Roof latch motor (LOCK) circuit is short | NG | ||
| LATCH VALUE | State of roof latch | Lock | 0 |
| Halfway position | 1-77 | ||
| Unlock | 78 or more | ||
| LATCH LIMIT SW | State of roof latch | Roof is fully close and roof latch is in LOCK | CLOSE |
| Other than above | OPEN | ||
| LATCH STATE | State of roof latch | Initialization is not complete | NG |
| LOCK | CLOSE | ||
| Halfway position | MID | ||
| UNLOCK | OPEN | ||
| PS VALUE (DRAW) | State of parcel shelf | Top | Retractable hard top fully open state: 2246 Retractable hard top fully closed state: 2220 |
| Bottom | 1000 | ||
| PS VALUE (ROTA) | State of parcel shelf | Vertical | 3190 |
| Horizontal | Retractable hard top fully open state: 1340 Retractable hard top fully closed state: 1000 | ||
| PS OUT (UP) | Operation of parcel shelf | Up operation is in operation | ON |
| Other than above | OFF | ||
| Parcel shelf (UP) circuit is short | NG | ||
| PS OUT (DOWN) | Operation of parcel shelf | DOWN operation is in operation | ON |
| Other than above | OFF | ||
| Parcel shelf (DOWN) circuit is short | NG | ||
| PS OUT (VERT) | Operation of parcel shelf | Vertical operation is in operation | ON |
| Other than above | OFF | ||
| Parcel shelf (VERTICAL) circuit is short | NG | ||
| PS OUT (HORI) | Operation of parcel shelf | Horizontal operation is in operation | ON |
| Other than above | OFF | ||
| Parcel shelf (HORIZONTAL) circuit is short | NG | ||
| PS STATE (DRAW) | State of parcel shelf | For the details, refer to "PARCEL SHELF FUNCTION: SYSTEM DESCRIPTION " | 1-6 |
| State of parcel shelf status sensor (DRAW) is not recognized | NG | ||
| PS STATE (ROTA) | State of parcel shelf | For the details, refer to "PARCEL SHELF FUNCTION: SYSTEM DESCRIPTION " | 1-4 |
| State of parcel shelf status sensor (ROTATE) is not recognized | NG | ||
| ROOF VALUE | Roof status sensor signal | 0-1023 | |
| PUMP OUT (RH) | Operation of hydraulic pump motor | Turning clockwise | ON |
| Other than above | OFF | ||
| Hydraulic pump motor (RH) circuit is short | NG | ||
| PUMP OUT (LH) | Operation of hydraulic pump motor | Turning counterclockwise | ON |
| Other than above | OFF | ||
| Hydraulic pump motor (LH) circuit is short | NG | ||
| SWITCH VLV 1 OUT | Operation of switching valve 1 | Operate | ON |
| Stop | OFF | ||
| Switching valve 1 circuit is short | NG | ||
| SWITCH VLV 2 OUT | Operation of switching valve 2 | Operate | ON |
| Stop | OFF | ||
| Switching valve 2 circuit is short | NG | ||
| ROOF STATE | State of roof | For the details, refer to "RETRACTABLE HARD TOP SYSTEM: SYSTEM DESCRIPTION " | 1-42 |
| State of roof is not recognized | NG | ||
| HYDRAULIC STATE | State of hydraulic system | For the details, refer to "HYDRAULIC SYSTEM CONTROL FUNCTION: SYSTEM DESCRIPTION " | 1-22 |
| State of hydraulic system is not recognized | NG | ||
| ROOF SW (OPEN) | State of roof open/close switch | OPEN operation is in operation | ON |
| Other than above | OFF | ||
| ROOF SW (CLOSE) | State of roof open/close switch | CLOSE operation is in operation | ON |
| Other than above | OFF | ||
| ROOF LINK STATE | State of roof link | For the details, refer to "HYDRAULIC SYSTEM CONTROL FUNCTION: SYSTEM DESCRIPTION " | 1-8 |
| State of roof is not recognized | NG | ||
| TRUNK LINK SEN (RH) | State of trunk link lock (RH) | LOCK | ON |
| Other than above | OFF | ||
| Trunk link lock (RH) circuit is short or open | NG | ||
| TRUNK LINK SEN (LH) | State of trunk link lock (LH) | LOCK | ON |
| Other than above | OFF | ||
| Trunk link lock (LH) circuit is short or open | NG | ||
| TR ROOM LAMP SW | State of trunk lid (trunk room lamp switch) | Open | OFF |
| Other than above | ON | ||
| TRUNK STATUS SEN | State of trunk lid | Fully OPEN | ON |
| Other than above | OFF | ||
| Trunk status sensor circuit is short or open | NG | ||
| TRUNK OPEN OUT | Operation of trunk lid opener actuator | OPEN operation is in operation | ON |
| Other than above | OFF | ||
| Trunk lid opener actuator circuit is short | NG | ||
| FLPD LIMIT SW (DWN) | State of flipper door | Both of flipper door (LH/RH) are in DOWN position | ON |
| Other than above | OFF | ||
| FLPD LIMIT SW (UP) | State of flipper door | Both of flipper door (LH/RH) are in UP position | ON |
| Other than above | OFF | ||
| FLPD OUT (UP) | Operation of flipper door | UP operation is in operation | ON |
| Other than above | OFF | ||
| Flipper door motor (UP) circuit is short | NG | ||
| FLPD OUT (DWN) | Operation of flipper door | DOWN operation is in operation | ON |
| Other than above | OFF | ||
| Flipper door motor (DOWN) circuit is short | NG | ||
| FLPD STATE | State of flipper door | For the details, refer to "FLIPPER DOOR FUNCTION: SYSTEM DESCRIPTION " | 1, 2, 4 |
| State of flipper door is not recognized | NG | ||
| R WIN LH OUT (UP) | Operation of rear power window (LH) | UP operation is in operation | ON |
| Other than above | OFF | ||
| Rear power window LH (UP) circuit is short | NG | ||
| R WIN LH OUT (DWN) | Operation of rear power window (LH) | DOWN operation is in operation | ON |
| Other than above | OFF | ||
| Rear power window LH (DOWN) circuit is short | NG | ||
| R WIN RH OUT (UP) | Operation of rear power window (RH) | UP operation is in operation | ON |
| Other than above | OFF | ||
| Rear power window RH (UP) circuit is short | NG | ||
| R WIN RH OUT (DWN) | Operation of rear power window (RH) | DOWN operation is in operation | ON |
| Other than above | OFF | ||
| Rear power window RH (DOWN) circuit is short | NG | ||
| REAR DEF ON SIG | State of rear window defogger switch | While operating | ON |
| Stop | OFF | ||
| REAR DEF OUT | State of rear window defogger system | Operate | ON |
| Stop | OFF | ||
| Rear window defogger circuit is short | NG | ||
| R WIN CURENT (LH) | Current value to rear power window motor (LH) | 0-25.5 (A) | |
| R WIN CURENT (RH) | Current value to rear power window motor (RH) | 0-25.5 (A) | |
| RR WIN STATE (LH) | State of rear power window (LH) | Upper | UP |
| Halfway | MID | ||
| Lower end | DOWN | ||
| RR WIN STATE (RH) | State of rear power window (RH) | Upper | UP |
| Halfway | MID | ||
| Lower end | DOWN | ||
| RAP SIGNAL | State of RAP | Operate | ON |
| Stop | OFF | ||
| TR MODE SIGNAL | State of trunk mode signal | Output | ON |
| Stop | OFF | ||
| ROOF STATE (AUDIO) | State of roof | State of fully open | ON |
| Other than above | OFF | ||
| Roof state signal (audio) circuit is short | NG | ||
| ROOF BUZZER OUT | State of roof warning buzzer | Operate | ON |
| Stop | OFF | ||
| Roof warning buzzer circuit is short | NG | ||
| LOCAL COMM 1 | State of local communication 1 | Normal | OK |
| It is in sleep mode | SLEEP | ||
| Communication error | NG | ||
| LOCAL COMM 2 | State of local communication 2 | Normal | OK |
| It is in sleep mode | SLEEP | ||
| Communication error | NG | ||
| ROOF MODE | Roof operation mode | Normal | OK |
| Only close operation is possible | CLOSE | ||
| Operation is stop | STOP | ||
| Operation is inhibited | NG | ||
| POP-UP BAR DPLOY | State of pop-up bar | Normal | OK |
| State of deployment | NG | ||
| POP-UP BAR DIAG | Self-diagnosis result of popup bar | Normal | OK |
| Malfunctioning is detected | NG | ||
| SWITCH VLV COND | Diagnosis result of retractable hard top control unit | Diagnosis result of retractable hard top control unit | OK |
| Switching valve (1/2) system is malfunctioning | NG | ||
| PWR SOURCE COND | Power supply voltage state of retractable hard top control unit | Normal | OK |
| Malfunction | NG | ||
| CPU COND | Diagnosis result of retractable hard top control unit | CPU is normal | OK |
| CPU is not normal | NG | ||
| ROOF COND | Diagnosis result of retractable hard top control unit | Roof position is normal | OK |
| Roof position is not normal | NG | ||
| SENSOR COND | Diagnosis result of retractable hard top control unit | Hole sensor system is normal | OK |
| Hole sensor system is not normal | NG | ||
| IGN ON SIG (BCM) | Power position signal (via CAN from BCM) | ON | OK |
| Other than above | NG | ||
| VHCL STOP-METER | Vehicle speed signal (via CAN from meter and A/C amp.) | 0km/h | OK |
| Other than above | NG | ||
| CIRCUIT COND | Diagnosis result of retractable hard top control unit | Circuit system is normal | OK |
| Circuit system is not normal | NG | ||
| ROOF TIMEOUT | State of roof operation | Normal | OK |
| Malfunction | NG | ||
| CAN COMM | CAN communication status | Normal | OK |
| Malfunction | NG | ||
| THERMO PROTECT 1 | Thermo protection (Stage1) | In non-operation | OK |
| In operation | NG | ||
| SHIFT R SIG | Shift position | Other than R position | OK |
| R position | NG | ||
| PRMIT ENG ST (BCM) | Permit engine start signal | Signal is not received | OK |
| Signal is in receiving | NG | ||
| THERMO PROTECT-2 | Thermo protection (Stage2) | In non-operation | OK |
| In operation | NG | ||
| TONNEAU SW | Tonneau board | Set | OK |
| Other than above | NG | ||
| BRK LAMP SW (BCM) | Brake lamp switch signal (via CAN from BCM) | Brake is depressed | OK |
| Brake is released | NG | ||
| THERMO VALUE | Conversion value of thermo protection | 0-65535 | |
| PWR SOURCE VALUE | Power supply voltage value of retractable hard top control unit | 0-20 (V) | |
| ROOF INITIAL (OPEN) | State of performing roof position initialization | Registration of full open position is complete | OK |
| Registration of full open position is not complete | NG | ||
| ROOF INITIAL (CLOSE) | State of performing roof position initialization | Registration of full closed position is complete | OK |
| Registration of full closed position is not complete | NG | ||
| PSHELF INITIAL (ROTA) | State of performing parcel shelf position initialization | Registration of rotation position is complete | OK |
| Registration of rotation position is not complete | NG | ||
| PSHELF INITIAL (DRAW) | State of performing parcel shelf position initialization | Registration of draw position is complete | OK |
| Registration of draw position is not complete | NG | ||