LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2014 >> Q60 Base, 2D Convertible, Standard Trans >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Convertible) >> Ecu Diagnosis Information >> Retractable Hard Top Control Unit >> Reference Value >> Values On The Diagnosis Tool
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Values On The Diagnosis Tool

NOTE: The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.
CONSULT MONITOR ITEM DESCRIPTION

Monitor Item Condition Status/Value
LATCH LOCK SEN State of roof latch Lock ON
Other than above OFF
Roof latch lock sensor circuit is short NG
LATCH STATE SEN State of roof latch motor Operate ON <==> OFF
Stop ON or OFF
Roof latch lock sensor circuit is short NG
LATCH OUT (ULK) Operation of roof latch motor Unlock is in operation ON
Other than above OFF
Roof latch motor (UNLOCK) circuit is short NG
LATCH OUT (LCK) Operation of roof latch motor Lock is in operation ON
Other than above OFF
Roof latch motor (LOCK) circuit is short NG
LATCH VALUE State of roof latch Lock 0
Halfway position 1-77
Unlock 78 or more
LATCH LIMIT SW State of roof latch Roof is fully close and roof latch is in LOCK CLOSE
Other than above OPEN
LATCH STATE State of roof latch Initialization is not complete NG
LOCK CLOSE
Halfway position MID
UNLOCK OPEN
PS VALUE (DRAW) State of parcel shelf Top Retractable hard top fully open state: 2246 Retractable hard top fully closed state: 2220
Bottom 1000
PS VALUE (ROTA) State of parcel shelf Vertical 3190
Horizontal Retractable hard top fully open state: 1340 Retractable hard top fully closed state: 1000
PS OUT (UP) Operation of parcel shelf Up operation is in operation ON
Other than above OFF
Parcel shelf (UP) circuit is short NG
PS OUT (DOWN) Operation of parcel shelf DOWN operation is in operation ON
Other than above OFF
Parcel shelf (DOWN) circuit is short NG
PS OUT (VERT) Operation of parcel shelf Vertical operation is in operation ON
Other than above OFF
Parcel shelf (VERTICAL) circuit is short NG
PS OUT (HORI) Operation of parcel shelf Horizontal operation is in operation ON
Other than above OFF
Parcel shelf (HORIZONTAL) circuit is short NG
PS STATE (DRAW) State of parcel shelf For the details, refer to "PARCEL SHELF FUNCTION: SYSTEM DESCRIPTION " 1-6
State of parcel shelf status sensor (DRAW) is not recognized NG
PS STATE (ROTA) State of parcel shelf For the details, refer to "PARCEL SHELF FUNCTION: SYSTEM DESCRIPTION " 1-4
State of parcel shelf status sensor (ROTATE) is not recognized NG
ROOF VALUE Roof status sensor signal 0-1023
PUMP OUT (RH) Operation of hydraulic pump motor Turning clockwise ON
Other than above OFF
Hydraulic pump motor (RH) circuit is short NG
PUMP OUT (LH) Operation of hydraulic pump motor Turning counterclockwise ON
Other than above OFF
Hydraulic pump motor (LH) circuit is short NG
SWITCH VLV 1 OUT Operation of switching valve 1 Operate ON
Stop OFF
Switching valve 1 circuit is short NG
SWITCH VLV 2 OUT Operation of switching valve 2 Operate ON
Stop OFF
Switching valve 2 circuit is short NG
ROOF STATE State of roof For the details, refer to "RETRACTABLE HARD TOP SYSTEM: SYSTEM DESCRIPTION " 1-42
State of roof is not recognized NG
HYDRAULIC STATE State of hydraulic system For the details, refer to "HYDRAULIC SYSTEM CONTROL FUNCTION: SYSTEM DESCRIPTION " 1-22
State of hydraulic system is not recognized NG
ROOF SW (OPEN) State of roof open/close switch OPEN operation is in operation ON
Other than above OFF
ROOF SW (CLOSE) State of roof open/close switch CLOSE operation is in operation ON
Other than above OFF
ROOF LINK STATE State of roof link For the details, refer to "HYDRAULIC SYSTEM CONTROL FUNCTION: SYSTEM DESCRIPTION " 1-8
State of roof is not recognized NG
TRUNK LINK SEN (RH) State of trunk link lock (RH) LOCK ON
Other than above OFF
Trunk link lock (RH) circuit is short or open NG
TRUNK LINK SEN (LH) State of trunk link lock (LH) LOCK ON
Other than above OFF
Trunk link lock (LH) circuit is short or open NG
TR ROOM LAMP SW State of trunk lid (trunk room lamp switch) Open OFF
Other than above ON
TRUNK STATUS SEN State of trunk lid Fully OPEN ON
Other than above OFF
Trunk status sensor circuit is short or open NG
TRUNK OPEN OUT Operation of trunk lid opener actuator OPEN operation is in operation ON
Other than above OFF
Trunk lid opener actuator circuit is short NG
FLPD LIMIT SW (DWN) State of flipper door Both of flipper door (LH/RH) are in DOWN position ON
Other than above OFF
FLPD LIMIT SW (UP) State of flipper door Both of flipper door (LH/RH) are in UP position ON
Other than above OFF
FLPD OUT (UP) Operation of flipper door UP operation is in operation ON
Other than above OFF
Flipper door motor (UP) circuit is short NG
FLPD OUT (DWN) Operation of flipper door DOWN operation is in operation ON
Other than above OFF
Flipper door motor (DOWN) circuit is short NG
FLPD STATE State of flipper door For the details, refer to "FLIPPER DOOR FUNCTION: SYSTEM DESCRIPTION " 1, 2, 4
State of flipper door is not recognized NG
R WIN LH OUT (UP) Operation of rear power window (LH) UP operation is in operation ON
Other than above OFF
Rear power window LH (UP) circuit is short NG
R WIN LH OUT (DWN) Operation of rear power window (LH) DOWN operation is in operation ON
Other than above OFF
Rear power window LH (DOWN) circuit is short NG
R WIN RH OUT (UP) Operation of rear power window (RH) UP operation is in operation ON
Other than above OFF
Rear power window RH (UP) circuit is short NG
R WIN RH OUT (DWN) Operation of rear power window (RH) DOWN operation is in operation ON
Other than above OFF
Rear power window RH (DOWN) circuit is short NG
REAR DEF ON SIG State of rear window defogger switch While operating ON
Stop OFF
REAR DEF OUT State of rear window defogger system Operate ON
Stop OFF
Rear window defogger circuit is short NG
R WIN CURENT (LH) Current value to rear power window motor (LH) 0-25.5 (A)
R WIN CURENT (RH) Current value to rear power window motor (RH) 0-25.5 (A)
RR WIN STATE (LH) State of rear power window (LH) Upper UP
Halfway MID
Lower end DOWN
RR WIN STATE (RH) State of rear power window (RH) Upper UP
Halfway MID
Lower end DOWN
RAP SIGNAL State of RAP Operate ON
Stop OFF
TR MODE SIGNAL State of trunk mode signal Output ON
Stop OFF
ROOF STATE (AUDIO) State of roof State of fully open ON
Other than above OFF
Roof state signal (audio) circuit is short NG
ROOF BUZZER OUT State of roof warning buzzer Operate ON
Stop OFF
Roof warning buzzer circuit is short NG
LOCAL COMM 1 State of local communication 1 Normal OK
It is in sleep mode SLEEP
Communication error NG
LOCAL COMM 2 State of local communication 2 Normal OK
It is in sleep mode SLEEP
Communication error NG
ROOF MODE Roof operation mode Normal OK
Only close operation is possible CLOSE
Operation is stop STOP
Operation is inhibited NG
POP-UP BAR DPLOY State of pop-up bar Normal OK
State of deployment NG
POP-UP BAR DIAG Self-diagnosis result of popup bar Normal OK
Malfunctioning is detected NG
SWITCH VLV COND Diagnosis result of retractable hard top control unit Diagnosis result of retractable hard top control unit OK
Switching valve (1/2) system is malfunctioning NG
PWR SOURCE COND Power supply voltage state of retractable hard top control unit Normal OK
Malfunction NG
CPU COND Diagnosis result of retractable hard top control unit CPU is normal OK
CPU is not normal NG
ROOF COND Diagnosis result of retractable hard top control unit Roof position is normal OK
Roof position is not normal NG
SENSOR COND Diagnosis result of retractable hard top control unit Hole sensor system is normal OK
Hole sensor system is not normal NG
IGN ON SIG (BCM) Power position signal (via CAN from BCM) ON OK
Other than above NG
VHCL STOP-METER Vehicle speed signal (via CAN from meter and A/C amp.) 0km/h OK
Other than above NG
CIRCUIT COND Diagnosis result of retractable hard top control unit Circuit system is normal OK
Circuit system is not normal NG
ROOF TIMEOUT State of roof operation Normal OK
Malfunction NG
CAN COMM CAN communication status Normal OK
Malfunction NG
THERMO PROTECT 1 Thermo protection (Stage1) In non-operation OK
In operation NG
SHIFT R SIG Shift position Other than R position OK
R position NG
PRMIT ENG ST (BCM) Permit engine start signal Signal is not received OK
Signal is in receiving NG
THERMO PROTECT-2 Thermo protection (Stage2) In non-operation OK
In operation NG
TONNEAU SW Tonneau board Set OK
Other than above NG
BRK LAMP SW (BCM) Brake lamp switch signal (via CAN from BCM) Brake is depressed OK
Brake is released NG
THERMO VALUE Conversion value of thermo protection 0-65535
PWR SOURCE VALUE Power supply voltage value of retractable hard top control unit 0-20 (V)
ROOF INITIAL (OPEN) State of performing roof position initialization Registration of full open position is complete OK
Registration of full open position is not complete NG
ROOF INITIAL (CLOSE) State of performing roof position initialization Registration of full closed position is complete OK
Registration of full closed position is not complete NG
PSHELF INITIAL (ROTA) State of performing parcel shelf position initialization Registration of rotation position is complete OK
Registration of rotation position is not complete NG
PSHELF INITIAL (DRAW) State of performing parcel shelf position initialization Registration of draw position is complete OK
Registration of draw position is not complete NG