DTC Detection Logic
| DTC | CONSULT Screen Terms | DTC Detecting Condition | |||
|---|---|---|---|---|---|
| (Trouble Diagnosis Content) | [Malfunction Type] | ||||
| P2270 | 00 | O2 SENSOR B1 SENSOR 2 (O2 sensor signal biased/stuck lean bank 1 sensor 2) |
NO SUBTYPE INFORMATION | Diagnosis condition | - |
| Signal (terminal) | - | ||||
| Threshold | The signal from Oxygen Sensor (cylinder bank 1) is shifted towards LEAN. | ||||
| Diagnosis delay time | - | ||||
| 26 | SIG RTE OF CHNG BLW THRESHLD | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The signal from Oxygen Sensor (cylinder bank 1) is shifted towards LEAN. The signal change rate is below the permissible limit value. | ||||
| Diagnosis delay time | - | ||||