DTC Detection Logic
| DTC | CONSULT Screen Terms | DTC Detecting Condition | |||
|---|---|---|---|---|---|
| (Trouble Diagnosis Content) | [Malfunction Type] | ||||
| P0607 | 04 | CONTROL MODULE (Control module performance) |
SYSTEM INTERNAL MALFUNCTN | Diagnosis condition | - |
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is an internal malfunction. | ||||
| Diagnosis delay time | - | ||||
| 09 | COMPONENT MALFUNCTION | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is a component malfunction. | ||||
| Diagnosis delay time | - | ||||
| - | - | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. | ||||
| Diagnosis delay time | - | ||||
| 12 | CIRCUIT SHORT TO BATTERY | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is a short circuit to positive. | ||||
| Diagnosis delay time | - | ||||
| 14 | CIRC SHORT TO GRND OR OPEN | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is a short circuit to ground or an open circuit. | ||||
| Diagnosis delay time | - | ||||
| 16 | CIRC VOLT BELOW THRESHOLD | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. The limit value for electrical voltage has not been attained. | ||||
| Diagnosis delay time | - | ||||
| 18 | CIRC CRRNT BELOW THRESHLD | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. The limit value for current has not been attained. | ||||
| Diagnosis delay time | - | ||||
| 41 | GENERAL CHECKSUM ERROR | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is a general checksum error. | ||||
| Diagnosis delay time | - | ||||
| P0607 | 48 | CONTROL MODULE (Control module performance) |
SUPERVISION SOFTWARE ERROR | Diagnosis condition | - |
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is an error in the control memory. | ||||
| Diagnosis delay time | - | ||||
| 62 | SIGNAL COMPARE ERROR | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. The signal comparison error. | ||||
| Diagnosis delay time | - | ||||
| 64 | SIGNAL PLAUSIBILITY ERROR | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The control unit has a malfunction. There is an implausible signal. | ||||
| Diagnosis delay time | - | ||||