DTC Detection Logic
| DTC | CONSULT Screen Terms | DTC Detecting Condition | |||
|---|---|---|---|---|---|
| (Trouble Diagnosis Content) | [Malfunction Type] | ||||
| P0667 | 00 | CONT MODULE INTRNL TEMP SEN A (Control module internal temperature sensor "A" range/performance) |
NO SUBTYPE INFORMATION | Diagnosis condition | - |
| Signal (terminal) | - | ||||
| Threshold | The internal temperature sensor of the control unit has a malfunction. | ||||
| Diagnosis delay time | - | ||||
| 16 | CIRC VOLT BELOW THRESHOLD | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The internal temperature sensor of the control unit has a malfunction. The limit value for electrical voltage has not been attained. | ||||
| Diagnosis delay time | - | ||||
| 17 | CIRC VOLT ABOVE THRESHOLD | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The internal temperature sensor of the control unit has a malfunction. The limit value for electrical voltage has been exceeded. | ||||
| Diagnosis delay time | - | ||||
| 86 | SIGNAL INVALID | Diagnosis condition | - | ||
| Signal (terminal) | - | ||||
| Threshold | The internal temperature sensor of the control unit has a malfunction. There is an invalid signal. | ||||
| Diagnosis delay time | - | ||||