LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2017 >> Q60 Base, AWD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater & Air Conditioning Control System >> Basic Inspection >> System Setting >> Exhaust Gas/Outside Odor Detecting Sensor Sensitivity Adjustment Function >> How To Set
April 5, 2026: LEMON Manuals is launched! Read the announcement.

How To Set

G-20 With CONSULT

Perform the "GAS SENSOR ADJUSTMENT" of HVAC work support item.

Work Support Items Display Setting
GAS SENSOR ADJUSTMENT 2 More sensitive setting than display 1 (REC earlier than display 1.)
1 More sensitive setting than normal setting (REC earlier than normal operation.)
0* Normal
- 1 Less sensitive setting than normal setting (REC later than normal operation.)
- 2 Less sensitive setting than display - 1 (REC later than display - 1.)

* : Initial status

NOTE:

When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of WORK SUPPORT may be cancelled.