Air Flow Control
Air Flow Reduction Control During Stop/Start Operation
- A/C Auto Amp. reduces duty ratio of Blower Motor control signal to Blower Motor to decrease air flow.
- Due to reduced air flow, the amount of air that passes evaporator is reduced to moderate increase of evaporator temperature. This helps prevent stop/start prohibition condition (evaporator temperature) from being met and prolongs stop/start operation time.
- Also, decrease of voltage applied to Blower Motor reduces power consumption. This moderates alternator power output after engine is restarted.
NOTE:
During stop/start operation, air flow reduction control operation can be changed from "AIR FLOW REDUCTION SETTING" on "WORK SUPPORT" of CONSULT. Refer to SETTING OF AIR FLOW REDUCTION CONTROL DURING STOP/START OPERATION .