Diagnosis Procedure
- COMPONENT FUNCTION CHECK
With CONSULT
- Turn ignition switch ON.
- On CONSULT screen, select "ENGINE" >> "ACTIV TEST" >> "Check purging pressure control".
- Select "OPEN".
- Check that the indicated value of purge pressure sensor is between (-)1 - (+)1 kPa [(-)0.01 - (+)0.01 bar, (-)0.01 - (+)0.01 kg-cm2, (-)0.145 - (+)0.145 psi]
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO STEP 2 .
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Insert the fuse which pulled out.
- Disconnect EVAP control system pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
+ - Voltage EVAP control system pressure sensor Connector Terminal F173 3 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and EVAP control system pressure sensor harness connector.
+ - Continuity ECM EVAP control system pressure sensor Connector Terminal Connector Terminal F149 16 F173 3 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Check ECM power supply circuit. Refer to DIAGNOSIS PROCEDURE .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and EVAP control system pressure sensor harness connector.
+ - Continuity ECM EVAP control system pressure sensor Connector Terminal Connector Terminal F149 36 F173 1 Existed 11 2 - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Replace EVAP control system pressure sensor. Refer to EXPLODED VIEW WITH TORQUE SPECIFICATIONS .
NO
Repair or replace error-detected parts.