  1. PERFORM CALIBRATION OF DECEL G SENSOR (ABS) 

    Perform calibration of decel G sensor. Refer to Work Procedure (TYPE 1), Work Procedure (TYPE 2).

    GO TO 2.

  2. PREPARATION BEFORE CALIBRATION PROCEDURE 
    1. Park the vehicle on a level surface.
    2. Adjust air pressure of all tires to the specified pressure. Refer to Tire Air Pressure .

    GO TO 3.

  3. PERFORM CALIBRATION OF DECEL G SENSOR (TCM) 

    SYMBOL With CONSULT

    1. Turn ignition switch ON.
      CAUTION: Never start engine.
    2. Select "Work Support" in "TRANSMISSION".
    3. Select "G SENSOR CALIBRATION".
    4. Touch "Start".
      CAUTION: Do not rock or jounce the vehicle during "G sensor calibration".

    Is "COMPLETED" displayed?

    YES

    WORK END

    NO

    Perform steps 3 again.