Vacuum Regulator Valve
Ensure vacuum pressure of 1.5-2.7 in. Hg is obtained from "Z" port when vacuum of 14.9 in. Hg is applied to "S" port. See Fig 6 .
Ensure vacuum pressure of 1.5-2.7 in. Hg is obtained from "Z" port when vacuum of 14.9 in. Hg is applied to "S" port. See Fig 6 .