Installation Procedure
- Lubricate the NEW lower injector O-ring seals (4) with clean engine oil.
- Install the NEW O-ring seals (4) onto each injector, if necessary.
- Install the fuel rail.
- Apply a 5 mm (0.020 in) band of threadlock GM P/N 12345382 (Canadian P/N 10953489) or equivalent, to the threads of the fuel rail bolts.NOTE: Refer to Fastener Notice in Cautions and Notices.
- Install the fuel rail bolts.
Tighten: Tighten the bolts to 10 N.m (89 lb in).
- Connect the fuel pressure regulator vacuum line.
- Connect the fuel feed and return pipes (1) to the fuel rail. Refer to Quick Connect Fitting(s) Service (Metal Collar) .
- Position the upper engine wire harness over the engine.
- Install the upper engine wire harness retainer nut (1).
Tighten: Tighten the nut to 5 N.m (44 lb in).
- Install the PCV hose (with valve).
- Connect the following electrical connectors on the left hand side of the engine:
- EVAP purge solenoid (1)
- Knock sensor (2)
- MAP sensor (3)
- Main coil (5)
- Fuel injectors (4)
- Perform the following steps in order to Connect the fuel injector electrical connectors.
- Install the connectors to their corresponding injectors to ensure correct reassembly.
- Connect the fuel injector electrical connector.
- Push the CPA retainer (2) on the connector in 1 click.
- Repeat the steps for each injector electrical connector.
- Install the electrical harness to the clips on ignition coil bracket.
- Connect the following electrical connectors on the right hand side of the engine:
- Coil main electrical harness (1)
- ETC (2)
- Fuel injectors (3)
- Install the electrical harness to the clips on ignition coil bracket.
- Connect the generator electrical connector.
- Connect the MAF/IAT sensor electrical connector (1).
- Install the wire harness to the clip (1) on the cylinder head.
- Connect the A/C compressor pressure switch electrical connector (2).
- Install the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement
- Install the fuel fill cap.
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
- Use the following procedure in order to inspect for leaks:
- Turn the ignition ON, with the engine OFF, for 2 seconds.
- Turn the ignition OFF for 10 seconds.
- Turn the ignition ON, with the engine OFF.
- Inspect for fuel leaks.