Circuit/System Testing
- Ignition ON, verify that the IPC warning indicators are illuminated.
- If the IPC warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC.
- Ignition OFF, disconnect connector X1 at the electronic ECM.
- Ignition ON, verify that the MIL is not illuminated.
- If the MIL is illuminated inspect the MIL control circuit for a short to ground. If the circuit tests normal, replace the IPC.
- Ignition ON, verify that the MIL illuminates with a 3A fused jumper between the MIL control circuit X1-40 and ground.
- If the MIL does not illuminate test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal replace the ECM.