LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Jaguar >> 1995 >> XJS 2D Convertible, 4.0 7 >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Engine Controls - Sensor Operating Range Charts - 6.0L V12 >> Sensor Operating Range Charts
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Sensor Operating Range Charts

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
ENGINE COOLANT TEMPERATURE SENSOR RESISTANCE

Temperature °F (°C) (1) Ohms
32 (0) 5000-8000
50 (10) 3000-5000
68 (20) 2000-3000
86 (30) 1500-2000
104 (40) 1000-1500
122 (50) 700-1000
140 (60) 600-800
158 (70) 300-600
176 (80) 260-400
(1) Resistance values are approximate. Check sensor in water.
HEATED OXYGEN SENSOR VOLTAGE

Condition Volts
Lean .1
Rich .9
INTAKE AIR TEMPERATURE SENSOR RESISTANCE

Temperature °F (°C) (1) Ohms
32 (0) 5000-8000
50 (10) 3000-5000
68 (20) 2000-3000
86 (30) 1500-2000
104 (40) 1000-1500
122 (50) 700-1000
140 (60) 600-800
158 (70) 300-600
176 (80) 260-400
(1) Resistance values are approximate.