B14F0-19 Bank 'A' motor #2 Output - Circuit current above threshold: Action
- 18-way specification seating: Refer to the electrical circuit diagrams and check the seat cushion extension motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear DTC and retest
- 18-way specification seating: If fault persists, install a new seat cushion extension motor
- 12-way specification seating: Refer to the electrical circuit diagrams and check the head restraint motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear DTC and retest
- 12-way specification seating: If fault persists, install a new head restraint motor
- 8-way specification seating: Refer to the electrical circuit diagrams and check the seat forward/rearward motor circuit for short circuit to ground, short circuit to power. Repair circuit as required. Clear DTC and retest
- 8-way specification seating: If fault persists, install a new seat forward/rearward motor